Showing results: 346 - 360 of 2604 items found.
-
50-132-002 -
Pickering Interfaces Ltd.
The 50-132-002 32xSPDT relay module is part of our range of PCI, low cost, general purpose electro-mechanical relay modules which are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching modules do not have sufficient voltage or current carrying capability.
-
50-132-003 -
Pickering Interfaces Ltd.
The 50-132-003 39xSPST relay module is part of our range of PCI, low cost, general purpose electro-mechanical relay modules which are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching modules do not have sufficient voltage or current carrying capability.
-
N3303A -
Keysight Technologies
The Keysight N3303A is a 250 W (0-10A, 0-240V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3303A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3303A can also digitize waveforms.
-
N3302A -
Keysight Technologies
The Keysight N3302A is a 150 W (0-30A, 0-60V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3302A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3302A can also digitize waveforms.
-
N3306A -
Keysight Technologies
The Keysight N3306A is a 600 W (0-120A, 0-60V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3306A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3306A can also digitize waveforms.
-
N3305A -
Keysight Technologies
The Keysight N3305A is a 500 W (0-60A, 0-150V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3305A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3305A can also digitize waveforms.
-
N3307A -
Keysight Technologies
The Keysight N3307A is a 250 W (0-30A, 0-150V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3307A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3307A can also digitize waveforms.
-
N3304A -
Keysight Technologies
The Keysight N3304A is a 300 W (0-60A, 0-60V)electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3304A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3304A can also digitize waveforms.
-
PEWM-3C-1 -
EMSYST Ltd
The single-phase energy standard PEWM-3C-1-1 is used for a quick check on site of all types single-phase electricity meters – for active, reactive or apparent energy, electromechanical and electronic. The voltage and the current are measured at the same time. The current can be measured directly within 10A or 100A range or with current clamp to 100A. The current clamp is electronically compensated.
-
TG-xxxx series -
Tesient Instrument Co., Ltd
TG-xxxx series programmable power supplies are Tesient Instrument recently developed portable power products.The series consist of three basic modules:--- High current module--- Medium current module--- Voltage module
-
Samlex America, Inc Power Supplies
Power supplies convert Alternating Current (AC) into Direct Current (DC). There is a wide choice of input and output voltages and power capacity to meet your specific requirements. Samlex Power supplies spectrum includes:
-
MS-159 -
Misum Systech Co., Ltd.
This equipment used for F/W writing, Calibration and function test. It inspect current, voltage protection mode, consumption current and cell balancing measurement to check the state of BMS and applied to the full inspection and mass production.
-
E3640A -
Keysight Technologies
Output ratings (@ 0C to 40C)Range 1: 0 to 8 V / 3 ARange 2: 0 to 20 V / 1.5 AProgramming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHzNormal Mode Voltage: <5 mVpp / 0.5 mVrmsNormal Mode Current: <4 mArmsCommon Mode Current: <1.5 uArmsReadback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)
-
PGK 80 -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal
-
PGK 50 -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK 50. The portable, one-piece PGK 50 high-voltage test device for generating negative DC voltage up to 50 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal